Fluke ii910 Precision Acoustic Imager
Fluke ii910 Precision Acoustic Imager
Fluke ii910 Precision Acoustic Imager

Share:


Fluke ii910 Precision Acoustic Imager

Fluke ii910 Precision Acoustic Imager

Key features
  • New: MecQ™ mechanical scanning
  • PDQ Mode™: Capture and analyze partial discharge
  • On device partial Discharge classification & PRPD plot
  • LeakQ™: On device leak rate and cost calculation
  • Online CO2 emission reporting
  • Reduce outages and increase uptime
  • Cut costs and save energy everyday by finding and fixing PD
 

Product overview: Fluke ii910 Precision Acoustic Imager

Finally, an easy way to detect, locate and analyze partial discharge in one tool
Tired of spending too much time detecting partial discharge? Introducing the ii910 Precision Acoustic Imager, engineered to locate partial discharge, corona discharge as well as gas and vacuum leaks. The ii910 acoustic imaging camera's groundbreaking technology is a cost efficient, safe, effective, and comfortable tool for teams who inspect and maintain power distribution and industrial high voltage equipment.

The invisible threat….now you can see
Partial discharge is a serious issue that teams monitor everyday. Whether you are scanning insulators, transformers, switch gears or high voltage powerlines you need to be sure that you spot a problem quickly and early. Partial discharge that goes unchecked can cause blackouts, fires, explosions, or death from arc flashes. In addition to the danger that this can pose to the environment and human lives, it also has a very steep price tag. Having equipment go down can cost millions of dollars per hour and studies have shown that a single data center outage could cost as much as $8,851 per minute. On top of this, the Department of Energy estimated that outages cost the US economy $150 billion annually.

Key areas to scan for PD
  • Insulators
  • Transformers
  • High voltage powerlines
  • Switch gears
  • Arrestors
  • Busbars
  • High voltage coils
  • Breakers
  • Capacitors


Do it fast, Do it safe
The ii910 is the all-in-one tool you have been looking for when it comes to all your leak, PD, and mechanical issues. Everything you need is right at your fingertips. Quickly scan the area or environment and get all the pictures and videos you need with the simple one-button capture and large 7” touchscreen LCD. No additional tools or equipment needed. With no cumbersome secondary cables or devices needed, you have full mobility and greater flexibility to swap between detecting leak/PD/mechanical issues and fixing the issues.

Fluke safety you can trust with performance you value
The Fluke ii910 Precision Acoustic Imager is the perfect tool for high voltage electricians, electrical test engineers, and grid maintenance teams that are constantly inspecting and maintaining power distribution and industrial high voltage equipment. The ii910 provides a safe quick and easy way to detect and locate partial discharge in order to maintain high voltage equipment and prevent catastrophic events. With the SoundSight™ technology the ii910 translates the sounds that it hears into a visual representation so that you can quickly locate problem areas. The higher frequency capability of the ii910 allows for earlier detection to facilitate early maintenance planning that is why the ii910 has a frequency range of 2-100Khz.



Find and fix before flash
Partial discharge can cause a number of very serious and expensive problems from catastrophic equipment failure to lethal arc flashes. The only way to stop this from happening is to inspect and maintain the equipment properly. The ii910 Precision Acoustic Imager is built to make finding PD much more comfortable faster and easy. Gone are the days of wearing headphones and listening for very faint sounds or squinting at a small screen to locate issues. Everything you will need to locate issues from a large distance is in the ii910, no cords or other accessories hanging down and getting tangled. Simply pick it up, turn it on and start locating issues.

Safety you expect with the rugged product you trust
Safety is key when working on high voltage equipment and here at Fluke safety is all that matters, everything else is just a bonus. Due to the combination of specific microphone positions and a sophisticated algorithm the ii910 Precision Acoustic Imager can detect PD and Corona Discharge from 120 meters away. This means that you can stay even further than the required distance away while still being effective and efficient at finding all of the problem areas. With no external cords or dangling accessories the ii910 ensures that you wont get tangled up in any equipment as you do your rounds. In addition with the acoustic imaging technology being able to pick up reflections of sounds you don’t even need to have direct line of sight to locate a problem. This means you can locate PD without ever opening a cabinet.

Find it quickly, find it easily with no training
The ii910 is truly designed so that anyone can use it with little to no training. Tear up those certifications because you don’t need one to operate this tool. Simply turn on the ii910 with one button select your frequency range (or let the tool do that for you) and start scanning around immediately looking for PD, leaks, or mechanical areas of interest. Once you find a concerning image of a sound you can take a video or a photo to be used later after you have added any text annotation. If you want to know more details about a specific leak, PD, or potential mechanical issue, switch into PDQ, LeakQ, or MecQ mode.

LeakQ online reporting tool
  • Local PC installed application
  • No Leak Type selection (should be included at time of capturing the measurement)
  • Offers customization of reporting template

Fluke PDQ Mode™ Reporting Tool with Acoustic Imaging
  • Web (cloud) based solution
  • Standardized reporting template
  • Leak Type selection per capture

What's in the box:
  • ii910 Precision Acoustic Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap
 

Specifications: Fluke ii910 Precision Acoustic Imager
 
Sensors
Frequency band 2 kHz to 100 kHz
Detection range 0.5 to > 120 meters (1.6 to > 393 feet)*
Field of View 63 ° ± 5 °
Nominal frame rate 25 FPS
*Depending on ambient conditions
 
Built-in digital camera (visible light)
Field of View (FOV) 63 ° ± 5 °
Focus Fixed lens
Zoom 3 x Digital Zoom
Resolution 5 MP
 
Display
Size 7" LCD with backlight, under-sunlight readable
Resolution 1280 x 800 (1,024,000 pixels)
Touchscreen Capacitive
Acoustic image Yes, SoundMap™ image
 
Image storage
Storage capacity 20GB (>5000 pictures / >999 videos)
Image format Blended visual and SoundMap™.JPG or .PNG
Video format Blended visual and SoundMap™.MP4
Video length Up to 5 minutes
Digital export USB-C for data transfer
 
Acoustic Measurements
Measurement range (typical) 12.1 to 114.6dB SPL (±1dB SPL 2kHz)
4.4 to 101.2dB SPL (±2dB SPL 19kHz)
12.8 to 119.2dB SPL (±1dB SPL 35kHz)
19.8 to 116.1dB SPL (±3dB SPL 52kHz)
41.4 to 129.0dB SPL (±1dB SPL 80kHz)
54.4 to 135.5dB SPL (±1dB SPL 100kHz)
Auto max/min dB gain Auto or manual, user selectable
Frequency band selection User selectable through user-made presets or manual entry
Classification and quantification LeakQ™, MecQ™, and PDQ Mode™
Leak size and cost estimation /
Mechanical inspection /
Partial discharge type classification
 
Software
Ease of use Intuitive user interface
Trend graphs Frequency and dB scale
Spot markers dB level reading at center point of the image
Asset ID QR code based asset ID identification
Asset Inspection Status: 'As left', 'As found' ; 'Undetermined'
Photo notes Up to 4 photos notes for reference
Source Show single or multiple sources
Profile Preset capture profiles
Annotation: Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure.
Other Operating conditions; Weather notes
Leak values Leak costs; Leak volume; LeakQ™ scale
Actions Action requirements; Action priority level; Action notes
 
Battery
Batteries (field-replaceable, rechargeable) 2 x Rechargeable Li-ion
Battery life 6 hours/battery (product includes spare battery)
Battery charging time 3 hours
Battery charging system External charger
 
General Specifications
Standard palettes 3: Grayscale, Ironbow, Blue-Red
Operating temperature -10 °C to 40 °C (14 °F to 104 °F)
Storage temperature -20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity 10 % to 95 % non-condensing
Size (H x W x L) 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
Weight (battery included) 2.15 kg (4.7 pounds)
Ingress Protection (IP) IP40
Warranty 2 year
Fluke Premium Care Premium Care Standard**
Self-diagnostic notification Array-health test to identify when microphone array needs attention
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliant Yes
** Subject to regional availability  
 
Safety
General safety IEC 61010-1
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
 

Models: Fluke ii910 Precision Acoustic Imager

FLK-ii910

Includes:
  • Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap


 Inquiry - Fluke ii910 Precision Acoustic Imager